Clean-agent fire suppression for data centers and critical electronic spaces

Overview

Since water suppression damages equipment in data centers, clean-agent gas suppression is preferred under BYKHY Article 98. A data center fire suppression system requires uninterrupted protection with FM200, NOVEC 1230 or inert gas (IG01) together with very-early-warning aspirating detection (VESDA). A-Pro delivers extinguishing-concentration calculation, cylinder-bank sizing, pipe design and commissioning under one roof, protecting the critical load within milliseconds.

How it works

Clean-Agent Suppression

Residue-free suppression without damaging equipment using FM200, NOVEC 1230 or IG01 under TS ISO 14520.

Very Early Warning (VESDA)

Aspirating smoke detection identifies fire in the invisible, pre-smell stage.

Extinguishing Concentration Calc

Agent quantity and discharge time calculated per space volume, tightness and NOAEL/LOAEL safety limits.

Water-Sensitive Spaces

Gas suppression replaces water in server, UPS, panel, transformer and cable-gallery rooms (Article 98).

Pressure-Relief Damper

A relief damper balances the pressure generated during discharge, protecting the room and equipment.

Uninterrupted Operation

Clean agents leave no residue; the system is quickly returned to service, preserving business continuity.

Our delivery process

  1. 01

    Survey & Space Analysis

    Determine protected volume, tightness, critical load and existing detection infrastructure.

  2. 02

    Agent Selection & Calculation

    FM200/NOVEC/IG01 selection, extinguishing concentration and cylinder-bank sizing (TS ISO 14520).

  3. 03

    Engineering & Approval

    Pipe design, nozzle layout, pressure-relief damper and code approval.

  4. 04

    Supply & Installation

    Cylinder bank, pipework, nozzles, VESDA and suppression control panel.

  5. 05

    Discharge Test & Commissioning

    Door-fan (integrity) test, detection-suppression scenario and acceptance procedures.

  6. 06

    Maintenance & Cylinder Check

    Continuous readiness via periodic weighing, pressure checks and a service contract.

Maintenance & periodic inspection

TS ISO 14520 requires periodic inspection of gas systems; A-Pro keeps the data center ready to protect at any moment through cylinder weighing, integrity and panel tests.

  • Periodic cylinder-bank weighing and pressure check
  • Annual door-fan (integrity) test with reporting
  • VESDA aspirating pipe and sensitivity test
  • Suppression control panel and release-circuit test
  • Pressure-relief damper functionality check
  • Nozzle and pipework blockage inspection

Frequently asked questions

Why gas suppression in a data center?+

Because water damages electronic equipment and interrupts business continuity, clean-agent gas (FM200, NOVEC 1230, IG01) is preferred under BYKHY Article 98. The agent leaves no residue.

Which agent is suitable — FM200, NOVEC or inert?+

Selected by space size, occupancy, ceiling height and sustainability goal: FM200 for rapid discharge, NOVEC 1230 for low GWP, IG01 for environmentally friendly inert protection.

Is the system safe in occupied rooms?+

Yes. The design stays within NOAEL safety limits and is supported by an evacuation/delay scenario. A-Pro uses neither halon nor aerosol.

Can it be retrofitted to my existing server room?+

Yes. Room tightness is assessed with a door-fan test; after any required sealing improvements the gas system is installed.

How soon can the system be re-armed after discharge?+

Because clean agents leave no residue, the system is quickly re-armed after the room is ventilated and cylinders are refilled or replaced.

Related systems

Sectors

Let us engineer your facility’s fire safety to standard

Contact us for a free site survey within Ankara and a quote. Turnkey solution from design to commissioning.