Fire Detection & Alarm

Addressable and conventional detection, alarm and cause-effect

Overview

Fire detection and alarm systems detect smoke/heat early to trigger evacuation and suppression scenarios. A-Pro implements addressable and conventional panel design, detector layout and cause-effect integration.

How it works

Addressable Systems

Each detector is individually monitored at the panel for fast response in large facilities.

Conventional Systems

Economical zone-based detection for small-to-medium buildings.

Special Detection

Aspirating (VESDA), linear heat cable and beam detectors for challenging spaces.

Cause-Effect Integration

Automatic scenarios with suppression, smoke exhaust, elevators and voice evacuation.

Our delivery process

  1. 01

    Survey & Space Analysis

    Building type, ceiling heights and detection requirements assessment.

  2. 02

    System & Cause-Effect Design

    Addressable/conventional choice, detector layout and cause-effect matrix.

  3. 03

    Design & Approval

    Panel capacity, cabling and code/fire-department approval.

  4. 04

    Supply & Installation

    Panel, detector, call point and sounder installation.

  5. 05

    Testing & Commissioning

    Point-to-point testing and scenario verification.

  6. 06

    Maintenance & Monitoring

    Uninterrupted protection via periodic testing and panel monitoring.

Maintenance & periodic inspection

Detection systems must stay active at all times; A-Pro keeps detectors, panels and scenarios operational through periodic testing and maintenance.

  • Periodic detector function and contamination test
  • Panel fault/battery and supply check
  • Call point, sounder and beacon function test
  • Cause-effect (scenario) matrix verification
  • Suppression/evacuation integration testing

Frequently asked questions

Addressable vs. conventional?+

Addressable shows each detector separately with exact location; conventional gives zone-level information.

Where is detection mandatory?+

In accommodation, healthcare, retail, education and industrial buildings meeting BYKHY Article 75 / Annex-7 thresholds.

Does detection integrate with suppression?+

Yes. Cross-zone verification triggers gas/water suppression, smoke exhaust and voice evacuation automatically.

How often should it be tested?+

Periodic function testing of detectors and scenarios is recommended; A-Pro provides regular checks under a maintenance contract.

Can an existing panel be expanded?+

On addressable systems, if capacity allows, the loop can be extended and additional detectors/modules integrated.

Related systems

Let us engineer your facility’s fire safety to standard

Contact us for a free site survey within Ankara and a quote. Turnkey solution from design to commissioning.