Water-Based Fire Suppression
Wide-area protection with sprinklers and water mist
Overview
Water-based fire suppression systems control fires at an early stage across large volumes using automatic sprinklers and water mist solutions. A-Pro delivers hydraulic calculation, pump station design, pipework and commissioning under one roof.
How it works
Automatic Sprinklers
Heat-sensitive bulb/fusible link opens only in the fire zone, preventing unnecessary water damage.
Water Mist
High-pressure micron-sized droplets cool rapidly and dilute oxygen using far less water.
Pump Station
Electric + diesel fire pumps, jockey pump and pressure management for uninterrupted flow.
Hydraulic Design
Flow-pressure calculation and zoning per NFPA 13 / TS EN 12845.
Water suppression subsystems
Our delivery process
- 01
Survey & Risk Analysis
Site assessment with space inventory, hazard class and water-source review.
- 02
Hydraulic Calculation
Flow-pressure calculation and zoning per NFPA 13 / TS EN 12845.
- 03
Design & Approval
Engineering, pump selection and code/fire-department approval.
- 04
Supply & Installation
Pump station, pipework and sprinkler-head installation.
- 05
Testing & Commissioning
Pressure test, flow test and acceptance procedures on handover.
- 06
Maintenance & Monitoring
Continuous readiness via periodic testing and a service contract.
Maintenance & periodic inspection
BYKHY and TS EN 12845 require periodic inspection; A-Pro keeps the system ready to activate at any moment through a testing and maintenance contract.
- Weekly/monthly pump run and gauge checks
- Sprinkler head and valve position inspection
- Annual flow-pressure test with reporting
- Diesel fire pump fuel and battery maintenance
- Water tank level, cleanliness and refill checks
Frequently asked questions
Do sprinklers flood the whole building?+
No. Only the sprinkler heads in the fire zone activate, minimizing water damage.
Water mist vs. sprinkler?+
Water mist uses much smaller droplets and far less water for cooling and oxygen dilution; ideal for water-sensitive spaces.
Where are sprinklers mandatory?+
In high-rises, large hotels, malls and enclosed car parks meeting BYKHY Article 96 thresholds.
How often does it need maintenance?+
TS EN 12845 recommends weekly/monthly operator checks plus an annual test by an authorized firm; A-Pro offers a maintenance contract.
How long does installation take?+
It depends on facility size and existing infrastructure; after the survey we share the hydraulic calculation and a clear schedule.