Sprinkler Systems
Automatic sprinkler systems for commercial and public buildings
Overview
The sprinkler is the most widely used water-based system, automatically suppressing or controlling fire at its point of origin. A-Pro designs hydraulic calculations, pipe sizing and sprinkler layout by hazard class per TS EN 12845 and NFPA 13.
How it works
Hazard-Class Design
Flow/density calculation by light (LH), ordinary (OH) and high (HHP/HHS) hazard classes.
Automatic Actuation
Heat-activated sprinkler heads operate only in the fire zone, limiting water damage.
Hydraulic Calculation
Pipe sizing and pressure optimized via TS EN 12845 / NFPA 13 hydraulic calculation.
Wet & Dry Alternatives
Dry-pipe systems in freeze-prone areas; wet-pipe systems in normal spaces.
System types
Wet Pipe Sprinkler
Pipes are permanently filled with pressurised water; water discharges the instant a head opens. The most common type in heated, non-freezing spaces.
Dry Pipe Sprinkler
Pipes hold pressurised air/nitrogen; when a head opens the air vents and water follows. Used in freeze-prone areas such as car parks and cold stores.
Preaction
Water enters the pipes only when both detection and a sprinkler head are confirmed. Ideal for data centres and archives where accidental discharge is critical.
Deluge
All heads are open; on detection the entire zone is flooded simultaneously. Used for high fire-load industrial hazards.
Frequently asked questions
How does a sprinkler system work?+
Each sprinkler head opens at a set temperature and delivers water only to the fire area; not all heads open at once.
Which buildings require it?+
Hotels over 100 rooms/200 beds/21.50 m, malls over 2,000 m², enclosed car parks over 600 m² and non-residential buildings over 30.50 m are key examples (Article 96).
What is the difference between wet and dry pipe sprinklers?+
Wet systems keep pipes water-filled for instant discharge; dry systems keep pipes air-filled and are preferred in freeze-prone spaces.
Can a sprinkler head trigger by accident?+
Heads open only when they reach their threshold temperature (typically 68 °C); they do not self-trigger without a heat rise. Preaction systems add further protection against accidental discharge.
How much water damage does a sprinkler cause?+
Because only the head in the fire zone opens, water damage is far more limited than a fire-hose stream, and the fire is controlled at an early stage.