İçeriğe geç

Factories & Industry

Turnkey fire suppression for factories and industrial production facilities

Overview

In industrial facilities, fire risk varies by process, storage and the type of combustible material. A factory fire suppression system requires water, foam, gas suppression and detection as an integrated whole with hazard-class-specific risk analysis. A-Pro delivers risk analysis, hydraulic/concentration calculation, engineering, installation and commissioning under one roof. We start with a free site survey in Ankara and surrounding provinces.

How it works

Automatic Detection

Automatic detection is mandatory in industrial buildings above 21.50 m height or 7,500 m² (Annex-7).

Hazard-Based Suppression

Water, foam or gas suppression by combustible type; 1,000 m² compartments in high-hazard areas.

Warehouse & Rack Protection

Rapid suppression in high-bay warehouses with in-rack sprinklers and ESFR solutions.

Foam Suppression

Fluorine-free (F3/SFFF) foam suppression in processes with flammable liquids and fuels.

Process Risk Management

Dedicated suppression and explosion-mitigation systems against paint, chemical and dust-explosion risks.

Fire-Brigade Inlet

External intervention infrastructure with a hydrant line and fire-brigade inlet in large facilities.

Our delivery process

  1. 01

    Free Survey

    Determine process type, combustible inventory, storage height and hazard class.

  2. 02

    Risk & Hazard-Class Analysis

    Define fire load, explosion risk and the appropriate suppression method (water/foam/gas).

  3. 03

    Engineering & Approval

    Hydraulic/concentration calculation, compartment plan and code approval.

  4. 04

    Supply & Installation

    Pump station, sprinklers/ESFR, foam dosing, gas system and detection.

  5. 05

    Testing & Commissioning

    Pressure-flow test, foam-ratio test and acceptance procedures on handover.

  6. 06

    Maintenance & Monitoring

    Continuous readiness via a periodic maintenance contract without disrupting production.

Maintenance & periodic inspection

BYKHY and relevant standards require periodic inspection of industrial facilities; A-Pro keeps the system ready at any moment without disrupting production through a testing and maintenance contract.

  • Weekly/monthly fire-pump run and gauge checks
  • Sprinkler/ESFR head and alarm-valve inspection
  • Foam concentrate quantity, shelf-life and dosing test
  • Gas-system cylinder weighing and door-fan test
  • Detector and panel test
  • Hydrant and fire-brigade inlet pressure test

Frequently asked questions

What is the detection threshold in a factory?+

Automatic detection is mandatory in industrial buildings above 21.50 m height or 7,500 m² (Annex-7).

Which suppression system is suitable?+

Water, foam or gas suppression is selected by combustible and process type, determined through risk analysis.

What drives the cost of a factory fire suppression system?+

It depends on facility area, hazard class, storage height and the selected suppression method. A clear quote is shared after a free survey.

How is a high-bay warehouse protected?+

In-rack sprinklers and ESFR solutions suppress fire early at rack level.

Do you use fluorine in foam systems?+

No. A-Pro uses fluorine-free (F3/SFFF) foam concentrates, alcohol-resistant (AR-SFFF) for polar liquids.

Related systems

Sectors

Let us engineer your facility’s fire safety to standard

Contact us for a free site survey within Ankara and a quote. Turnkey solution from design to commissioning.