İçeriğe geç

Enclosed Car Parks

Turnkey fire suppression for enclosed car parks and vehicle-lift structures

Overview

With the spread of electric vehicles, fire risk in enclosed car parks has increased. A car park fire suppression system requires automatic detection — mandatory since the 1 July 2025 amendment — together with sprinklers and smoke ventilation as an integrated whole. A-Pro delivers hydraulic calculation, smoke-control design, fire-department approval and commissioning under one roof. We start with a free site survey in Ankara and surrounding provinces.

How it works

Automatic Detection (Mandatory)

The 1 July 2025 amendment made automatic fire detection mandatory in enclosed car parks.

Sprinkler Requirement

Sprinklers are mandatory in enclosed car parks exceeding 600 m² OR taking more than 10 vehicles via vehicle lift (Article 96).

Smoke Ventilation

Jet-fan and mechanical smoke extraction keep escape routes clear and ease intervention.

EV Charging Risk

Dedicated detection and suppression measures against increased thermal-runaway risk in EV charging zones.

Fire-Brigade Riser

A fire-brigade riser is mandatory in car parks whose floor area exceeds 1,000 m² (Article 97).

Freeze Protection

Protection against freezing in unheated car parks with dry-pipe sprinklers or antifreeze solutions.

Our delivery process

  1. 01

    Free Survey

    Determine total area, storey count, vehicle capacity, EV charging zone and ventilation state.

  2. 02

    Risk & Conformity Analysis

    Inspect the existing system and define detection and smoke-ventilation needs.

  3. 03

    Engineering & Approval

    Sprinkler hydraulic calculation, jet-fan smoke-control design and fire-department approval.

  4. 04

    Supply & Installation

    Pump station, sprinklers, detection, jet fans and smoke-extraction systems.

  5. 05

    Testing & Commissioning

    Pressure-flow test, smoke-control scenario and acceptance procedures on handover.

  6. 06

    Maintenance & Monitoring

    Continuous readiness and conformity tracking via a periodic maintenance contract.

Maintenance & periodic inspection

BYKHY and TS EN 12845 require periodic inspection of enclosed car parks; A-Pro keeps the system ready to activate at any moment through a testing and maintenance contract.

  • Weekly/monthly fire-pump run and gauge checks
  • Sprinkler head and alarm-valve inspection
  • Detector and panel test
  • Jet fan and smoke-extraction fan functionality check
  • Dry-pipe air pressure and freeze-protection check
  • Hose cabinet and fire-brigade riser pressure test

Frequently asked questions

Is detection mandatory in an enclosed car park?+

Yes, the 1 July 2025 amendment made automatic fire detection mandatory in enclosed car parks.

In which car park is a sprinkler mandatory?+

Sprinklers are mandatory in enclosed car parks exceeding 600 m² or taking more than 10 vehicles via vehicle lift (Article 96).

What drives the cost of a car park fire suppression system?+

It depends on total area, storey count, vehicle capacity, ventilation and existing infrastructure. A clear quote is shared after a free survey.

What is done against electric-vehicle fires?+

Thermal-runaway risk is managed in EV charging zones with early detection, dense sprinkler coverage and dedicated suppression where needed.

How is an unheated car park protected against freezing?+

Dry-pipe sprinklers or antifreeze solutions protect the system in freeze-prone areas.

Related systems

Sectors

Let us engineer your facility’s fire safety to standard

Contact us for a free site survey within Ankara and a quote. Turnkey solution from design to commissioning.