Hospitals & Healthcare
Turnkey fire suppression for hospitals and inpatient healthcare facilities
Overview
In inpatient healthcare, fire safety is critical due to evacuation difficulty and the need for uninterrupted service. A hospital fire suppression system requires automatic detection, water suppression and clean-agent suppression in critical spaces as an integrated whole; operating theaters and ICUs are protected with continuity. A-Pro delivers detection design, sprinkler hydraulic calculation, gas-suppression design and commissioning under one roof. We start with a free site survey in Ankara and surrounding provinces.
How it works
Automatic Detection
Addressable automatic detection is mandatory in inpatient healthcare above 6.50 m height or 1,000 m² (Annex-7).
Water Suppression
Integrated sprinkler protection in corridors, patient rooms and common areas.
Gas in Critical Spaces
Clean-agent suppression instead of water in imaging (MRI/CT), server and panel rooms (FM200/NOVEC/IG01, Article 98).
Horizontal Evacuation & Compartments
Horizontal evacuation zones and fire compartments planned for mobility-restricted patients.
Pressurization & Smoke Control
Escape stairs pressurized; smoke extraction keeps escape routes clear.
Uninterrupted Operation
Suppression scenarios preserving service continuity in theaters, ICUs and laboratories.
Our delivery process
- 01
Free Survey
Determine bed capacity, floor area, height and critical spaces (theater, imaging, server).
- 02
Risk & Conformity Analysis
Inspect the existing system and prioritize evacuation difficulty and critical spaces.
- 03
Engineering & Approval
Detection design, sprinkler hydraulic calculation, gas-suppression calculation and fire-department approval.
- 04
Supply & Installation
Addressable detection, sprinklers, gas-suppression cylinder bank and pressurization systems.
- 05
Testing & Commissioning
Detection scenario, pressure-flow test and gas-system door-fan test on handover.
- 06
Maintenance & Monitoring
Continuous readiness via a periodic maintenance contract without disrupting service.
Maintenance & periodic inspection
BYKHY requires periodic inspection of inpatient healthcare facilities; A-Pro keeps the hospital ready to protect at any moment without disrupting service continuity through a testing and maintenance contract.
- Addressable detector and panel test
- Sprinkler head and alarm-valve inspection
- Critical-space gas-system cylinder weighing and door-fan test
- Escape-stair pressurization fan check
- Hose cabinet and hydrant pressure test
- Emergency lighting and signage battery check
Frequently asked questions
What is the detection threshold in a hospital?+
Addressable automatic fire detection is mandatory in inpatient healthcare above 6.50 m height or 1,000 m² (Annex-7).
How are theaters and imaging protected?+
Clean-agent suppression (FM200/NOVEC/IG01) is preferred in water-sensitive critical spaces; A-Pro uses neither halon nor aerosol.
What drives the cost of a hospital fire suppression system?+
It depends on bed capacity, floor area, number of critical spaces and existing infrastructure. A clear quote is shared after a free survey.
Can installation be done while the hospital is operating?+
Yes. Block/department-based phased installation minimizes disruption to service continuity during installation and revision.
How are mobility-restricted patients protected?+
Horizontal evacuation zones and fire compartments allow patients to be moved to a safe area, protecting them without full evacuation.